Reference Loudness−24 LUFS
Dialogue Loudness
> −22 LUFS → Warn< −26 LUFS → Warn
True Peak Max
> −2 dBTP → Fail

ATSC A/85 Long-form Monitor

A practical PLVS monitor for dialogue-led ATSC long-form content.

StandardBroadcastDialogueMonitoring

Release 1Requires PLVS 0.20.0+

Download

How to Use

Copy Profile, then paste in PLVS outside a text field to review the import.

Or download the file and choose Settings → Saved Items → Import….

Confirm the import, then select the Profile in PLVS. Importing does not apply it automatically.

Details

This is a monitoring aid, not an A/85 conformance measurement. A/85 calls for dialogue-gated measurement over the complete composite mix using BS.1770-1 without the relative-level gate added by later versions. PLVS instead uses an open voice-activity detector followed by its existing gated Dialogue Integrated calculation. Results therefore depend on detection quality and only evaluate when PLVS has a dialogue estimate. Use a conforming system for delivery certification. ATSC's LKFS values are displayed as numerically equivalent LUFS in PLVS.

Reference Loudness
−24 LUFS
Dialogue Loudness
> −22 LUFS → Warn< −26 LUFS → Warn
True Peak Max
> −2 dBTP → Fail
File Size
755 bytes
File Checksum

sha256:4cbfaf833ff827e863e4c48b54d3eb71efd2bdcd7a880191bc7de384fdd39ae9

Sources

Release History

Release 1

2026-10-14 · published

Initial monitoring release with explicit non-conformance limitations.